Explosionproof Type: Intrinsic Safety type, ExibI |
 |
Measuring
Range: 0 100°C
(Special order is needed when requires 0 150°C) |
 |
Measuring
Accuracy:
When 0 115°C , ± 3.0°C ; when 116 150°C , ±6.0°C |
 |
Adjusting
of Action Temperature:
The user can adjust the action temperature and reset temperature by 4-bit setting switch on the switching board. If it is used to detect the head roll's surface temperature, action temperature is recommended as 84.8°C. |
| |
| On/Off Status |
All OFF |
1 ON
Other OFF |
2 ON
Other OFF |
3 ON
Other OFF |
4 ON
Other OFF |
| Action Temperature |
98.8°C |
84.4°C |
63.8°C |
53.9°C |
39.9°C |
| Reset Temperature |
61.0°C |
53.8°C |
45.8°C |
37.1°C |
28.4°C |
|
 |
Spectral Response Range: 7 18 µm |
 |
Measuring
Distance: 0  1200 mm.
Measuring the head roll, 200  300 mm is recommended. |
 |
Output:
200  1000 Hz
frequency signal or a set of non-potential conversion contact
signal |
 |
Power
Supply:
DC 12  18 V
(must be Intrinsic Safety power supply when used in coal mine underground),
<50 mA |
 |
Transmission Distance: 2 km |