Explosionproof Type: Mine-used Flameproof and Intrinsic Safety type |
 |
Measuring
Range: 0 40% CH |
 |
Measuring Error: %CH |
|
| Working Area |
Measuring Range |
Basic Error |
Low Concentration
|
0.00  1.00 |
 0.10 |
1.00  3.00 |
 0.10% of truel value |
3.00  4.00 |
 0.30 |
High Concentration
|
4  40 |
 0.10% of true value
|
|
 |
Response Time: < 20s |
 |
Remote Control Range: Distance  5m, angle  120° |
 |
Alarm Point: 0.3%  4.00%CH  , can set arbitrarily ( Default 1.0%CH  ) |
 |
Alarm Mode: Red light sparkling, buzzer sounding
>80dB (with 18 V power supply, distance 1 m) |
 |
Power
Breaking Point: Can be set freely in 0.3%  4.0%CH  (Default 1.5%CH  ) |
 |
Power
Breaking Output: With load resistance 1000  , high level  3V, low level  0.5V |
 |
Power Reset Point: Can be set freely in 0.3%  4.0%
CH  (Default 1.0%CH  ) |
 |
Output: |
| |
| KGJ23-1: |
Low concentration: 200  1000 Hz,
linear to 0  4.00%CH  ;
High concentration: 1200  2000 Hz, linear to 0  40.0%CH  ;
When load resistance >1.5 k  ,
high level output >3 V, low level output <0.5 V. When
using the transmission cable with C  0.06 ¦ÌF/km,
L  0.8mH/km,
R  19 ¦¸/km,
the transmission distance shall be  2 km; The red LED H10 is for indicating frequency output |
| KGJ23-2: |
Load resistance
0  500  ,
and this model has no function of power off output,
and the on/off output displays the measuring range of
high and low concentration methane:
When the on/off output is low level signal, then 1  5 mA is linear to 0  4.00%CH  ;
When the on/off output is high level signal, then1  5 mA is linear to 0  40.0%CH  |
| KGJ23-3: |
RS485 port, communication
baud rate 1200 bps |
|
 |
Working Voltage: DC 9  24 V |
 |
Working Current:  80 mA when DC18 V |
 |
Rated Flow: 200 ml/min |
 |
Overall Dimensions: 266 ¡Á 120 ¡Á 45 (mm) |
 |
Weight: 1 kg |