Explosionproof Type: Mine-used Flameproof and Intrinsic Safety type |
 |
Measuring
Range: 0 4% CH |
 |
Measuring Error: %CH |
|
| Measuring Range |
Basic Error |
0.00  1.00 |
 0.10 |
1.00  3.00 |
 0.10% of true value |
3.00  4.00 |
 0.30
|
|
 |
Response Time: < 20s |
 |
Remote Control Range: Distance 5m, angle 120° |
 |
Alarm Point: 0.3% 4.00%CH , can set arbitrarily ( Default 1.0%CH ) |
 |
Alarm Mode: Red light sparkling, buzzer sounding
>80dB (with 18 V power supply, distance 1 m) |
 |
Power
Breaking Point: Can be set freely in 0.3%  4.0%CH  (Default 1.5%CH  ) |
 |
Power Reset Point: Can be set freely in 0.3%  4.0%CH  (Default 1.0%CH  ) |
 |
Output:
KGJ16B-1: 200  1000 Hz, when load resistance>1.5 k  and high level output>3 V, the red LED H10 is for indicating frequency output
KGJ16B-1: constant current 1  5 mA, load resistance 0  500 
KGJ16B-3: RS485 port, communication baud rate 1200 bit/s |
 |
Working Voltage: DC 9  24V |
 |
Working Current:  65mA when DC18V |
 |
Rated Flow: 200 ml/min |
 |
Overall Dimensions: 266 × 120 × 45 (mm) |
 |
Weight: 1 kg |
 |
Support online calibration |