Explosionproof Type: Mine-used Flameproof and Intrinsic Safety type |
 |
Measuring
Range: 0 10% CH |
 |
Measuring Error: %CH |
|
| Measuring Range |
Basic Error |
0.00  1.00 |
 0.10 |
1.00  3.00 |
 0.10% of truel value |
3.00  4.00 |
 0.30 |
4.00  10.00 |
 0.10% of true value
|
|
 |
Response Time: 30 s |
 |
Remote Control Range: Distance 5 m |
 |
Alarm Point: 0.3% 4.00%CH , can set arbitrarily ( Default 1.5%CH ) |
 |
Alarm Mode: Red light sparkling, buzzer sounding
>80 dB (with 18 V power supply, distance 1 m) |
 |
Power
Breaking Point: Can be set freely in 0.3% 4.0%CH (Default 1.5%CH ) |
 |
Power Reset Point: Can be set freely in 0.3% 4.0%
CH (Default 1.0%CH ) |
 |
Output:
frequency 200 1000 Hz, output high level >3 V (load resistance >1.5 k )
RS485 interface, baud rate 1200 bit/s |
 |
Working Voltage: DC 9 24 V |
 |
Working Current: 110 mA |
 |
Rated Flow: 200 ml/min |
 |
Overall Dimensions: 266 × 110 × 45 (mm) |
 |
Weight: 1 kg |